Note: Oil-canning is not considered grounds for rejection
of any panel system. Oil-canning can occur in any panel with
wide flat sections. Heavier gauge, embossing, striations, flatter
sub-frame systems and support from a solid sub-deck can all
help to minimize oil-canning. |
Description: A
unique feature of this panel is a vertical leg that is a side
joint that is mechanically seamed with an electric seamer for a
weather tight finish. This panel features concealed clips and
easy
to handle 16" wide panels custom cut to the desired length.
This panel can be installed directly over purlins or bar joists.
It does not require a solid substructure for support. This roof
system has several different UL90 construction numbers. Gauge: 24
(standard) with 22 gauge available on request
Length: Maximum 50'
(standard), other lengths are available as special requests
Dimensions: 12" or 16" wide by 2" high
Fasteners: A choice of
concealed fastening clips is available for this panel system
including UL rated clips. These clips hold the
panel firmly in place without unsightly exposed fasteners. Each
clip system offers the ability to accommodate thermal movement.
Finish: Galvalume
Manufactured: Multiple facilities within NCI
Usage: This panel
is a structural panel that spans up to five feet on purlins,
or can be used as an architectural panel over
solid
deck. This flat panel is designed with striations as an option
to minimize
oil-canning. It is designed to meet the ever-changing specifications
and other industry codes.
Limitations: Recommended for roof
slopes of 1/2:12 or greater. Oil canning is not a reason for
rejection.
Features:
- Factory applied mastic inside of female leg of panel is
standard
- Swaged end laps
- Heavier gauges, striation and embossing (optional)
- Design flexibility
- Roof runs without end lap panels maybe erected from
either direction
- Roof to wall transition
- 80% less exposed fasteners than traditional side lap
panels and all
- fasteners are long life
- The side lap has been tested for air infiltration and
water penetration
- under ASTM E283 and E331 methods
- Vertical Leg
- Insulated with thermal blocks
- High or low floating clips available
- High or low fixed clips available
- Panel available in Signature 300 Series
- UL 90
- Panel has striations
Benefits:
- Watertightness and easier erection
- Improved erection and improved appearance
- Minimizes oil canning
- Optimize economy
- Flexible and convenient erection
- Creates a trimless eave
- Increased weather tightness and improved appearance
- Minimal air infiltration and water penetration and
acceptability among specifiers
- Better transition to hip, valleys, and roof openings
- High energy efficiency system
- Allows roof to expand an contract maximizing weather
tightness
- Varying insulation thickness available
- 20 year finish warranty
- Lower insurance costs
- Helps with oil canning
|